Motorized Louver Damper & Flue Gas Butterfly Valve

High-Temperature Multi-Blade Flue Gas & Hot Air Flow Regulation Damper

Home / Products / Flow Control Valves / Motorized Louver Damper & Flue Gas Butterfly Valve
MLV SERIES

Motorized Louver Damper & Flue Gas Butterfly Valve

HSX Motorized Louver Dampers and Flue Gas Butterfly Valves feature multiple aerodynamic synchronized blades driven by intelligent electric or electro-hydraulic actuators. Engineered for high-temperature flue gas, hot air, and corrosive exhaust ducts in power plants, cement kilns, and metallurgical smelters with <= 0.5% seal leakage.

Duct Dimension DN400 – DN4000 (Round) / 500×500 – 5000×5000 mm
Design Temperature -20°C to +650°C (High-Temperature Stainless/Alloy)
Operating Pressure -10 kPa to +30 kPa (Flue Gas Flow)
Seal Tightness 99.5% Standard / 100% Zero-Leakage with Air Purge

Model Series & Engineering Parameters High-Temp Damper

DUCT SIZE Up to 5,000 mm
MAX TEMP Up to +650°C
SEAL RATING 99.5% – 100% Tightness
Model Series Duct Size (mm) Number of Blades Actuator Type Max Temp (°C) Leakage Rate
MLV-600 600 x 600 mm 2 – 3 Blades 2SA3 Electric / DYT 350°C <= 0.5%
MLV-1000 1,000 x 1,000 mm 4 – 5 Blades 2SA3 Electric / DYT 450°C <= 0.5%
MLV-1500 1,500 x 1,500 mm 6 – 8 Blades Intelligent Electric 550°C <= 0.5%
MLV-2500 2,500 x 2,500 mm Multi-Section Electro-Hydraulic 650°C <= 0.2%
MLV-4000+ 3,000 – 5,000 mm Heavy Louver Dual Sync Drive 650°C 100% Air Purge

Ordering Nomenclature Guide: MLV - [Duct Width x Height mm] - [Temp Code: 350/450/650] - [Actuator Spec] - [Air Purge: Y/N].

Motorized Louvre & Butterfly Valve Engineering Manual (PDF)
Download PDF Specs ↓
DESIGN ADVANTAGES

Aerodynamic Low-Torque Blade Balancing

Opposed-blade movement balances aerodynamic wind loads.

01

Aerodynamic Opposed-Blade Motion

Adjacent blades rotate in opposite directions, balancing airflow torque and ensuring linear flow throttling characteristics.

02

Thermal Expansion Relief Shafts

Outboard bearing housings with self-aligning graphite bushings isolate bearings from high flue gas heat.

03

100% Zero-Leakage Air Seal Option

Dual-blade cavity with heated seal air blower creates positive pressure barrier, preventing hazardous flue gas bypass.

04

Corrosion & Acid Dewpoint Resistance

316L, 254SMO, or ceramic-coated blades resist sulfuric and hydrochloric acid condensation in desulfurization ducts.

APPLICATIONS

Proven in Severe Plant Environments

Delivering high thrust and zero-drift actuation across critical heavy industrial facilities.

Thermal Power FGD & SCR

Flue gas desulfurization bypass, selective catalytic reduction inlet isolation.

Cement Kiln Preheaters

Tertiary air duct dampers, raw mill exhaust fan isolation.

Steel Sintering & Pelleting

Main exhaust louver dampers, waste heat recovery hot air regulation.

Chemical Incineration Flues

Hazardous waste incinerator quench tower dampers.

DIRECT TECHNICAL RFQ

Request Technical Quotation & Sizing Proposal

Submit your required parameters, operating duty, or project drawings for Motorized Louver Damper & Flue Gas Butterfly Valve. Our export engineering team will review your specifications and provide an official quotation within 24 hours.

This field is required.
This field is required.
This field is required.
Product of Interest
This field is required.
Please describe your application, required specifications, quantity, operating conditions and destination country.
This field is required.
This field is required.

Need Help with Tailored Industrial Solutions? We Are Experts!

Contact Us →